Sashin Samar da Wutar Wuta yana canza shigarwar DC zuwa fitarwar DC

PDC-2200WC babban inganci ne na PSU wanda ke juyar da shigarwar DC zuwa fitarwar DC, wanda ke da fa'idar aikace-aikace. PSU tana da kewayon shigarwar DC na -38V zuwa -72V, yana ba da ƙimar ƙimar 53.5V. Yana ba da tashoshin sadarwa na CAN, sadarwa tare da aika lambobin lantarki na lantarki ga mai watsa shiri don sauƙaƙe kulawa da gudanarwa.


Linkedin
43f45020
384b0 ku
754c4db4
6ec95a4a

Cikakken Bayani

Tags samfurin

PSU tana da kewayon shigarwar DC na -38V zuwa -72V, yana ba da ƙimar ƙimar 53.5V. Yana ba da tashoshin sadarwa na CAN, sadarwa tare da aika lambobin lantarki na lantarki ga mai watsa shiri don sauƙaƙe kulawa da gudanarwa.
Hakanan yana tallafawa N+1, N+N redundancy (N≥2). Har zuwa 32 PSUs za a iya daidaita su don amfanin sakewa.
PDC-2200WC PSU tana goyan bayan sa ido da ayyuka masu ban tsoro.

Siffofin
Wurin shigar da wutar lantarki: -38 V zuwa -72 V, ƙarfin fitarwa: 2200 W
Inganci: 94% (Vin = -53.5 V, 40% kaya)
Zurfin x Nisa x Tsawo: 485.0 mm x106.5 mm x 41.0 mm (19.094in. x 4.193in. x 1.614 in.)
Nauyi: ≤ 3.0kg
Tsawon lokacin: 8 ms
Zafi-swappable
Tare da fan mai sarrafa sauri
Goyan bayan shigarwar ƙarancin wuta, juyar da kariyar polarity
Goyon bayan wuce gona da iri, iyakancewa na yanzu, gajeriyar kewayawa, kariyar keɓewar kuskure
Goyi bayan kariyar zafin jiki, kariyar laifin fan
Hanyoyin sadarwa na CAN don sarrafawa, shirye-shirye da saka idanu
TUV, UL, CE takaddun shaida da rahoton CB
Haɗu da IEC 62368-1, buƙatun RoHS6
Aikace-aikace:

  • Masu ba da hanya tsakanin hanyoyin sadarwa/Masanya
  • Sabar/Ajiya
  • Kayan aikin sadarwa

Raba Yanzu:
Har zuwa 32 PDC-2200WCs ana iya daidaita su don daidaitawa da yawa. Ana aiwatar da rabawa na yanzu akan sadarwar CAN
PSU tana amfani da fanka don watsar da zafi. Mai fan yana jawo iska daga gaba kuma yana fitar da iska daga baya don sanyaya, kuma yana daidaita saurinsa bisa yanayin yanayin zafi.


  • Na baya:
  • Na gaba: